EMERSON VE4050S2K1C0 VE4050S2KICO Analog output module The I/O interface carrier plugs on to the power/controller carrier. The power/controller carrier supplies the system power and communications between the I/O interfaces and the controller. The controller processes the I/O interface information. An additional power/controller carrier is required for use with redundant controllers.
Get your I/O subsystem up and running efficiently with the DeltaV horizontal mount I/O carriers. The power/controller carrier contains internal power buses. You don’t need to use external cabling to connect the system power supply to the DeltaV controller and the I/O interface carriers.
EMERSON VE4003S2B10 Analog Input Card Detection Total control. The controller manages all control activities for the I/O interface channels. It also manages all communication functions for the communications network. Time stamping, alarming, and trend objects are also managed within the controller. The controller executes all control strategy with execution speeds up to every 100 ms.
EMERSON A6210 9199-00003 Thrust Differential Expansion Module Control strategy complexity and control module scan rates determine overall controller performance and application size. A redundant controller may be added to back up an MQ Controller online. The standby controller comes online automatically, with a bumpless transition. For more information, refer to the I/O Redundancy product data sheet.
EMERSON A6110 9199-00001 AMS Shaft Relative Vibration Monitor This A6110 Module feature provides automatic restart of the controller in case of a power failure. The restart is completely autonomous because the entire control strategy is stored in NVM RAM of the controller for this purpose. Simply set the restart state of the controller to current conditions.
Data protection. All online changes made to control parameters are automatically stored for later upload into the engineering database. This way, the system always retains a complete record of all the data that has been changed online.
Advanced operations. The MQ Controller is equipped to handle the DeltaV Batch option, as well as advanced control functions.
Data pass-through. The controller is equipped with the ability to pass smart HART® information from field devices to any workstation node in the control network. This means you can take advantage of applications, such as Asset Management Solutions AMS Device Manager, that enable you to remotely manage the HART information contained in your HART or FOUNDATION Fieldbus equipped devices.