NI Voltage Input Module SCXI-1104C 32 Differential Channel.The National Instruments SCXI-1104C (Part Number: 776572-04C, 183087H-05) Voltage Input Module has 32 differential channels and is created for the signal conditioning of higher voltage signals. This model comes with a 10 kHz cut-off frequency filter. If the user wants to utilize the NI SCXI-1104C in a ribbon-cabled multichassis SCXI system, then they need to use the SCXI-1346 multichasis adapter with it. If the user chooses not to auto-detect the SCXI modules, then they must add the modules individually. This can be accomplished by following the instructions in the user manual.
While utilizing software, the user can arrange pin 1,2, 4, or 19 to link to the analog ground of the Voltage Input Module. The user can utilize the pin that is linked to the analog ground as an analog power ground tie point to the SCXI-1104C. An important fact to remember is that the NI SCXI-1104C analog output is not overvoltage-protected. Therefore, applying external voltages to this output can damage the module. The analog outputs are short-circuit protected though. The device has a recommended warm-up time of 20 minutes and an operating temperature of 0 to 50 °C.
The National Instruments SCXI-1104C module can be calibrated by applying precision voltages to the channel inputs and/or grounding the channel inputs. This module should be recalibrated a minimum of once per year or anytime it is operated outside of the specified temperature range. The NI SCXI-1104C Voltage Input Module can be calibrated with a multiranging 8.5 digital multimeter. The device has a cut-off frequency of 10 kHz. When users complete a measurement with NI Software, the driver automatically uses the calibration constants to adjust the measured voltages to the correct values.
The NI-DAQ version 6.5.1 (or higher) is the software driver used in running the SCXI-1104C. To install the driver, an Application Development Environment such as LabVIEW, BridgeVIEW, LabWindows/CVI, Visual Basic (ComponentWorks), C,C++, VirtualBench, or Measure is required. The device has a 50-pin male ribbon cable back connector and a 96-pin male DIN C front connector.
SCXI-1104C Obsolete Status has been announced by National Instruments, but the module will still be available for purchase and repairs by Apex Waves. The SCXI-1104C can be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated annually or biennially to ensure accuracy.
SCXI-1000 SCXI-1300
SCXI-1001 SCXI-1302
SCXI-1100 SCXI-1303
SCXI-1102 SCXI-1304
SCXI-1102B SCXI-1305
SCXI-1102C SCXI-1308
SCXI-1104 SCXI-1320
SCXI-1104C SCXI-1324
SCXI-1104D SCXI-13244
SCXI-1120D SCXI-1325
SCXI-1121 SCXI-1326
SCXI-1122 SCXI-1327
SCXI-1124 SCXI-1328
SCXI-1125 SCXI-1331
SCXI-1126 SCXI-1332
SCXI-1127 SCXI-1333
SCXI-1140 SCXI-1334
SCXI-1141 SCXI-1335
SCXI-1143 SCXI-1336
SCXI-1160 SCXI-1337
SCXI-1162 SCXI-1338
SCXI-1162HV SCXI-1339
SCXI-1163 SCXI-1346
SCXI-1163R SCXI-1349
SCXI-1180 SCXI-1377
SCXI-1190 SCXI-1378
SCXI-1192 SCXI-1600
Reviews
There are no reviews yet.